Residential Plan / Drawing Requirements
Pickaway County Building Department · 124 West Franklin Street, Circleville, Ohio 43113 · 740-477-8282 · Revised 9/11/2020
All pertaining items must be reflected on submitted drawing(s).
Use this checklist when preparing the drawings that accompany a Residential Building Plan Approval Application. Two sets of plans are required.
Footer / Foundation
- Footer size (width and depth)
- Foundation size and material
- Pier footings size and location
- Foundation anchoring: type and spacing
- 6″ of foundation above grade
- Waterproofing and type
- Perimeter drain to sump or natural drain
- Foundation insulation
Slab / Crawl Details
- 6 mil vapor barrier under slab or in crawl space
- Gravel under slab or in crawl space
- Crawl space vent locations (if applicable)
- Crawl space access: size and location (if applicable)
Floor Construction
- Floor joist: type, size and spans
- Supporting beams: type and size
- Floor material and size
- Fasteners for treated lumber to be of approved type
Wall Construction
- Sill plate size
- Sill termite protection
- Wall stud size
- Double top plate
- Header sizes
- Sidewall sheathing: type and size
- Exterior wall covering: type
- Exterior sidewall insulation
- Attic insulation
- Band board or crawl space insulation
Stair Details
- Tread and riser details (max. riser 8¼″, min. tread 9″)
- Handrail height (30″–38″ above tread nosing)
- Guardrail openings (max. 4″ opening, 6″ between stair treads)
Roof / Ceiling Construction
- Truss or rafter
- Rafter size and span
- Sealed truss drawings (if applicable)
- Roof sheathing: type and size
- Underlayment type
- Roofing material
- Ice-guard
- Roof/attic ventilation
- Soffit venting
- Uplift protection
Interior Details
- Room sizes
- Safety glazing where required
- Door locations
- Window locations
- Egress windows where required
- Room uses
Plumbing Details
- Building drain size
- Water service size
- Water supply: public or private
- Sewer system: public or private
- Sump pump location (if applicable)
- Hot water tank location
- Material type of DWV and water distribution system
Electric Details
- Electric panel size and location
- Electric meter location and service type
- Electric service wire type and size
- Grounding details
- Panel schedule: breaker uses and sizes shown
- Smoke detector locations and details
- Arc fault breakers where required
- GFCI in required locations
- Lighting — switching / receptacle locations
- Appliance locations (range, washer, dryer, oven, etc.)
Heating / Cooling Details
- Furnace/AC type and size
- Furnace fuel
- Furnace/AC location
- Supply duct sizing
- Return duct sizing
- Exhaust fans for bathrooms
- “Res Check” energy code requirements met (US Department of Energy “Res Check”)
- Supply register locations
- Return air location
Post Frame Buildings
- Girts size and spacing
- Knee bracing
- Wood post dimensions
- Header connection
- Roof purlins — size and spacing